Repair Actions/HSIO: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
(→Repair) |
||
Line 14: | Line 14: | ||
== Repair == | == Repair == | ||
* The HSIO bus connects the main die of the [[GPU]] to the [[eDRAM]] die. As all of these components are on the GPU substrate, it is not possible to service the chip internally. | * The [[HSIO]] bus connects the main die of the [[GPU]] to the [[eDRAM]] die. As all of these components are on the GPU substrate, it is not possible to service the chip internally. | ||
* The only way to fix the E 73, E 74, and E 82 errors is to replace the GPU. | * The only way to fix the E 73, E 74, and E 82 errors is to replace the GPU. | ||
{{Debug and Repair}} | {{Debug and Repair}} |
Latest revision as of 15:24, 31 December 2023
Note This page is a technician's reference. You will need Schematic and/or Boardview files to follow these steps. |
1021/E 73
- ERROR_HSIO_TRAINING_FAILED
Occurs if the HSIO training fails due to an unresponsive or malfunctioning eDRAM. The SMC enters EC_XSS, the E 73 UEM will be displayed, and the 1021 code is displayed on the front panel.
1022/E 74 and 1102/E 82
- ERROR_HSIO_CALIBRATION_FAILED
Occurs if the HSIO calibration fails due to an unresponsive or malfunctioning eDRAM. The SMC enters EC_XSS, the E 74 or E 82 UEM will be displayed, and the 1022 or 1102 code is displayed on the front panel.
- On the Original Xbox 360, 1022/E 74 is displayed.
- On the Xbox 360 S and Xbox 360 E, 1102/E 82 is displayed.
Repair
- The HSIO bus connects the main die of the GPU to the eDRAM die. As all of these components are on the GPU substrate, it is not possible to service the chip internally.
- The only way to fix the E 73, E 74, and E 82 errors is to replace the GPU.