Repair Actions/0031: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
(3 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{{See also|Errors|Secondary Error Codes}} | {{See also|Errors|Secondary Error Codes}} | ||
{{ | {{RepairNote}} | ||
This error has a different meaning on the [[Original Xbox 360]] vs the [[Xbox 360 S]] and [[Xbox 360 E]]. It is not used on [[Xenon (Motherboard)|Xenon]] motherboards. | This error has a different meaning on the [[Original Xbox 360]] vs the [[Xbox 360 S]] and [[Xbox 360 E]]. It is not used on [[Xenon (Motherboard)|Xenon]] motherboards. | ||
Line 27: | Line 27: | ||
== VREG Circuit == | == VREG Circuit == | ||
* Everything in this section must be checked quickly, as the SMC will shut down power upon entering EC_FATAL | * Everything in this section must be checked quickly, as the SMC will shut down power upon entering EC_FATAL | ||
* Check if V_5P0 and V_MEM | * Check if V_5P0 and V_MEM are present | ||
* If they are, replace the PWM driver and recheck PWRGD | * If they are, replace the PWM driver and recheck PWRGD | ||
* If they aren't, check VREG and PWM driver | * If they aren't, check VREG and PWM driver | ||
= S and E = | |||
;ERROR_V_5P0 | |||
VREG_V5P0_PWRGD is driven high by the V_5P0 controller as long as the rail is within tolerance. If V_5P0 ever drops out of tolerance, the signal is de-asserted, causing the [[SMC]] to enter [[Errors#EC_FATAL|EC_FATAL]] and the 0031 code to be displayed on the front panel. | |||
== Short Circuit == | |||
* Check if V_5P0 is shorted | |||
* If it is, check circuit components to localize short | |||
** Lift at least 1 pin of the inductor to isolate the rail before checking | |||
== Enable and Power Good == | |||
* Everything in this section must be checked quickly, as the SMC will shut down power upon entering EC_FATAL | |||
* Check VREG_V5P0_EN signal and pulldown | |||
** If pulldown is fine but signal is missing, replace Southbridge | |||
* Check VREG_V5P0_PWRGD | |||
** If present, replace Southbridge | |||
** If missing, check pullup | |||
*** If pullup is fine, continue below | |||
== VREG Circuit == | |||
* Everything in this section must be checked quickly, as the SMC will shut down power upon entering EC_FATAL | |||
* Check if V_5P0 is present | |||
* If it is, replace the PWM driver and recheck PWRGD | |||
* If it isn't, check VREG and PWM driver | |||
{{Debug and Repair}} |
Latest revision as of 14:26, 20 December 2023
Note This page is a technician's reference. You will need Schematic and/or Boardview files to follow these steps. |
This error has a different meaning on the Original Xbox 360 vs the Xbox 360 S and Xbox 360 E. It is not used on Xenon motherboards.
Original
- ERROR_V_5P0_V_MEM
VREG_V5P0_VMEM_PWRGD is driven high by the V_5P0/V_MEM controller as long as the rail is within tolerance. If V_5P0 or V_MEM ever drops out of tolerance, the signal is de-asserted, causing the SMC to enter EC_FATAL and the 0031 code to be displayed on the front panel.
Short Circuit
- Check if V_5P0 or V_MEM are shorted
- If it is, check the rail to localize short
- Lift at least 1 pin of the inductor to isolate the rails before checking
- If V_MEM is shorted, check decoupling capacitors near each RAM
- If all components are fine but a short on V_MEM remains, replace the RAM and/or GPU
Enable and Power Good
- Everything in this section must be checked quickly, as the SMC will shut down power upon entering EC_FATAL
- Check VREG_V5P0_EN and VREG_V1P8_EN signals and pulldowns
- If pulldowns are fine but signal is missing, replace Southbridge
- Check VREG_V5P0_VMEM_PWRGD
- If present, replace Southbridge
- If missing, check pullup
- If pullup is fine, continue below
VREG Circuit
- Everything in this section must be checked quickly, as the SMC will shut down power upon entering EC_FATAL
- Check if V_5P0 and V_MEM are present
- If they are, replace the PWM driver and recheck PWRGD
- If they aren't, check VREG and PWM driver
S and E
- ERROR_V_5P0
VREG_V5P0_PWRGD is driven high by the V_5P0 controller as long as the rail is within tolerance. If V_5P0 ever drops out of tolerance, the signal is de-asserted, causing the SMC to enter EC_FATAL and the 0031 code to be displayed on the front panel.
Short Circuit
- Check if V_5P0 is shorted
- If it is, check circuit components to localize short
- Lift at least 1 pin of the inductor to isolate the rail before checking
Enable and Power Good
- Everything in this section must be checked quickly, as the SMC will shut down power upon entering EC_FATAL
- Check VREG_V5P0_EN signal and pulldown
- If pulldown is fine but signal is missing, replace Southbridge
- Check VREG_V5P0_PWRGD
- If present, replace Southbridge
- If missing, check pullup
- If pullup is fine, continue below
VREG Circuit
- Everything in this section must be checked quickly, as the SMC will shut down power upon entering EC_FATAL
- Check if V_5P0 is present
- If it is, replace the PWM driver and recheck PWRGD
- If it isn't, check VREG and PWM driver