Repair Actions/0032: Difference between revisions

From XenonLibrary
Jump to navigation Jump to search
No edit summary
No edit summary
Line 27: Line 27:
* If it is, replace the PWM driver and recheck PWRGD
* If it is, replace the PWM driver and recheck PWRGD
* If it isn't, check VREG and PWM driver
* If it isn't, check VREG and PWM driver
{{Debug and Repair}}

Revision as of 20:29, 23 March 2023

Note  This page is a technician's reference and is not intended to teach diagnosis and repair of electronic circuits.

This error only exists on the Xbox 360 S Trinity motherboards. It may exist on Corona and newer as well, this is still being analyzed.

ERROR_V_CPUVCS

VREG_CPUCORE_VCS_PWRGD is driven high by the V_CPUVCS controller as long as the rail is within tolerance. If V_CPUVCS ever drops out of tolerance, the signal is de-asserted, causing the SMC to enter EC_FATAL and the 0032 code to be displayed on the front panel.

Short Circuit

  • Check if V_CPUVCS is shorted
  • If it is, check circuit components to localize short
    • Lift at least 1 pin of the inductor to isolate the rail before checking

Enable and Power Good

  • Everything in this section must be checked quickly, as the SMC will shut down power upon entering EC_FATAL
  • Check CPU_SRVID signal, pullup, and pulldown
    • If pullup and pulldown are fine but signal is missing, replace CGPU
  • Check VREG_CPUCORE_VCS_PWRGD
    • If present, replace Southbridge
    • If missing, check pullup
      • Note that the pullup for this signal is part of the V_CPUCORE circuit
      • If pullup is fine, continue below

VREG Circuit

  • Everything in this section must be checked quickly, as the SMC will shut down power upon entering EC_FATAL
  • Check if V_CPUVCS voltage is within tolerance
  • If it is, replace the PWM driver and recheck PWRGD
  • If it isn't, check VREG and PWM driver