Secondary Error Codes

From XenonLibrary
Revision as of 21:24, 23 March 2023 by Octal450 (talk | contribs) (→‎0031)
Jump to navigation Jump to search

A database of Secondary Error Codes on the Xbox 360. Refer to this page for instructions on retrieving the code from the console.

SMC Errors

These errors are generated by the SMC.

0001

ANA_V12P0_PWRGD is driven high by the ANA (later HANA) as long as the V_12P0 rail is within tolerance. If V_12P0 ever drops out of tolerance, the signal is de-asserted, causing the SMC to enter EC_FATAL and the 0001 code to be displayed on the front panel.

Hex Name Description Type Repair Guide
0x01 ERROR_V_12P0 ANA_V12P0_PWRGD negated unexpectedly EC_FATAL Repair Actions/0001

0002

VREG_CPU_PWRGD is driven high by the V_CPUCORE controller as long as the rail is within tolerance. If V_CPUCORE ever drops out of tolerance, the signal is de-asserted, causing the SMC to enter EC_FATAL and the 0002 code to be displayed on the front panel.

Hex Name Description Type Repair Guide
0x02 ERROR_V_CPUCORE VREG_CPU_PWRGD negated unexpectedly EC_FATAL Repair Actions/0002

0003

Xbox 360 (Original)

VREG_GPU_PWRGD is driven high by the V_GPUCORE controller as long as the rail is within tolerance. If V_GPUCORE ever drops out of tolerance, the signal is de-asserted, causing the SMC to enter EC_FATAL and the 0003 code to be displayed on the front panel.

Hex Name Description Type Repair Guide
0x03 ERROR_V_GPUCORE VREG_GPU_PWRGD negated unexpectedly EC_FATAL Repair Actions/0003
Xbox 360 S and Xbox 360 E

VREG_V3P3_PWRGD is driven high by the V_3P3 controller as long as the rail is within tolerance. If V_3P3 ever drops out of tolerance, the signal is de-asserted, causing the SMC to enter EC_FATAL and the 0003 code to be displayed on the front panel.

Hex Name Description Type Repair Guide
0x03 ERROR_V_3P3 VREG_V3P3_PWRGD negated unexpectedly EC_FATAL Repair Actions/0003

0010

The SMC communicates with the ANA/HANA via the SMBus. If communication is lost, the SMC enters EC_FATAL and the 0010 code is displayed on the front panel.

Hex Name Description Type Repair Guide
0x04 ERROR_NO_ANA ANA/HANA is not responding to reads or writes EC_FATAL Repair Actions/0010

0011

The SMC monitors the CPU thermal diode as reported by the ANA/HANA. If the CPU temperature exceeds the Trip Temperature defined in the SMC Config, the SMC enters EC_THERMAL and the 0011 code is displayed on the front panel.

Hex Name Description Type Repair Guide
0x05 ERROR_THERMAL_CPU CPU thermal overload EC_THERMAL Repair Actions/Thermal

0012

The SMC monitors the GPU thermal diode as reported by the ANA/HANA. If the GPU temperature exceeds the Trip Temperature defined in the SMC Config, the SMC enters EC_THERMAL and the 0012 code is displayed on the front panel.

Hex Name Description Type Repair Guide
0x06 ERROR_THERMAL_GPU GPU thermal overload EC_THERMAL Repair Actions/Thermal

0013

The SMC monitors the eDRAM thermal diode as reported by the ANA/HANA. If the eDRAM temperature exceeds the Trip Temperature defined in the SMC Config, the SMC enters EC_THERMAL and the 0013 code is displayed on the front panel.

Hex Name Description Type Repair Guide
0x07 ERROR_THERMAL_EDRAM eDRAM thermal overload EC_THERMAL Repair Actions/Thermal

0020

After GPU power and clocking are available, the SMC starts seqUnReset which releases the GPU from reset. It then waits for the GPU to assert GPU_RST_DONE. If the GPU_RST_DONE signal is not asserted in the time allotted, EC_BOOT will be reported. The SMC will retry 4 more times. If on the final attempt, GPU_RST_DONE is still not asserted, the SMC remains in EC_BOOT and the 0020 code is displayed on the front panel.

Hex Name Description Type Repair Guide
0x08 ERROR_GPU_RST_DONE GPU_RST_DONE signal not asserted after seqUnReset time passed EC_BOOT Repair Actions/0020

0021

After receiving GPU_RST_DONE during seqUnReset, the SMC monitors the PCIe L0 status and waits for the link to enter the L0 state. If the link does not enter the L0 state in the time allotted, EC_BOOT will be reported. The SMC will retry 4 more times. The SMC will retry 4 more times. If on the final attempt, the link still does not enter L0 state, the SMC remains in EC_BOOT and the 0021 code is displayed on the front panel.

Hex Name Description Type Repair Guide
0x09 ERROR_NO_PCIE PCIe link did not enter L0 after seqUnReset time passed EC_BOOT Repair Actions/0021

0022

After the PCIe link has entered the L0 state during seqUnReset, the SMC releases the CPU from reset. The CPU will run the Bootloaders and start the XSS. When the XSS starts, it will attempt to retrieve the power up cause from the SMC. If the SMC does not receive GetPowerUpCause in the time allotted, EC_BOOT will be reported. The SMC will retry 4 more times. If on the final attempt, GetPowerUpCause is still not received, the SMC remains in EC_BOOT and the 0022 code is displayed on the front panel.

Hex Name Description Type Repair Guide
0x0A ERROR_NO_HANDSHAKE CPU did not send GetPowerUpCause to SMC EC_BOOT Repair Actions/0022

0023

Xenon

The SMC communicates with the Backup Clock Generator via the SMBus. If communication is lost, the SMC enters EC_FATAL and the 0023 code is displayed on the front panel.

Hex Name Description Type Repair Guide
0x0B ERROR_NO_CLOCKCHIP Clock chip is not responding to reads or writes EC_FATAL Repair Actions/0023
Xbox 360 S and Xbox 360 E

VREG_VEDRAM_PWRGD is driven high by the V_CPUEDRAM controller as long as the rail is within tolerance. If V_CPUEDRAM ever drops out of tolerance, the signal is de-asserted, causing the SMC to enter EC_FATAL and the 0023 code to be displayed on the front panel.

Hex Name Description Type Repair Guide
0x0B ERROR_V_CPUEDRAM VREG_VEDRAM_PWRGD negated unexpectedly EC_FATAL Repair Actions/0023

0030

The SMC communicates with the ANA/HANA via the SMBus. If the thermal registers read as zero, the SMC enters EC_FATAL and the 0030 code is displayed on the front panel.

Hex Name Description Type Repair Guide
0x0C ERROR_NO_TEMPERATURES CPU did not send GetPowerUpCause to SMC EC_FATAL Repair Actions/0030

0031

Xbox 360 (Original) (Except Xenon)

VREG_V5P0_VMEM_PWRGD is driven high by the V_5P0/V_MEM controller as long as the rail is within tolerance. If V_5P0 or V_MEM ever drops out of tolerance, the signal is de-asserted, causing the SMC to enter EC_FATAL and the 0031 code to be displayed on the front panel.

Hex Name Description Type Repair Guide
0x0D ERROR_V_5P0_V_MEM VREG_V5P0_VMEM_PWRGD negated unexpectedly EC_FATAL Repair Actions/0031
Xbox 360 S and Xbox 360 E

VREG_V5P0_PWRGD is driven high by the V_5P0 controller as long as the rail is within tolerance. If V_5P0 ever drops out of tolerance, the signal is de-asserted, causing the SMC to enter EC_FATAL and the 0031 code to be displayed on the front panel.

Hex Name Description Type Repair Guide
0x0D ERROR_V_5P0 VREG_V5P0_PWRGD negated unexpectedly EC_FATAL Repair Actions/0031

0032

Xbox 360 S and Xbox 360 E

VREG_CPUCORE_VCS_PWRGD is driven high by the V_CPUVCS controller as long as the rail is within tolerance. If V_CPUVCS ever drops out of tolerance, the signal is de-asserted, causing the SMC to enter EC_FATAL and the 0032 code to be displayed on the front panel.

Hex Name Description Type Repair Guide
0x0E ERROR_V_CPUVCS VREG_CPUCORE_VCS_PWRGD negated unexpectedly EC_FATAL Repair Actions/0032

0033

Xbox 360 S and Xbox 360 E

VREG_VMEM_PWRGD is driven high by the V_MEM controller as long as the rail is within tolerance. If V_MEM ever drops out of tolerance, the signal is de-asserted, causing the SMC to enter EC_FATAL and the 0033 code to be displayed on the front panel.

Hex Name Description Type Repair Guide
0x0F ERROR_V_MEM VREG_VMEM_PWRGD negated unexpectedly EC_FATAL Repair Actions/0033

XSS Errors

These errors are generated by the XSS and reported to the SMC.

0100

The 2BL tries to retrieve the vendor ID from each memory chip. If any of the IDs cannot be read or mismatch, EC_XSS will be reported. The SMC will retry 4 more times. If on the final attempt, the IDs still cannot be read or mismatch, the SMC remains in EC_XSS and the 0100 code is displayed on the front panel.

Hex Name Description Type Repair Guide
0x10 ERROR_NBINIT_MEM_VENDOR_ID Memory vendor ID read failed or mismatched EC_XSS Repair Actions/0100

0101

During 2BL memory initialization, if data cannot be written for read strobe training, EC_XSS will be reported. The SMC will retry 4 more times. If on the final attempt, data still cannot be written, the SMC remains in EC_XSS and the 0101 code is displayed on the front panel.

Hex Name Description Type Repair Guide
0x11 ERROR_NBINIT_MEM_READ_STROBE_DATA_WRITE Unable to write data for read strobe training EC_XSS Repair Actions/0101

0102

During 2BL memory initialization, if read strobe delay training fails, EC_XSS will be reported. The SMC will retry 4 more times. If on the final attempt, training still fails, the SMC remains in EC_XSS and the 0102 code is displayed on the front panel.

Hex Name Description Type Repair Guide
0x12 ERROR_NBINIT_MEM_READ_STROBE_DELAY_TRAINING Memory read strobe delay training failed EC_XSS Repair Actions/0102

0103

During 2BL memory initialization, if write strobe delay training fails, EC_XSS will be reported. The SMC will retry 4 more times. If on the final attempt, training still fails, the SMC remains in EC_XSS and the 0103 code is displayed on the front panel.

Hex Name Description Type Repair Guide
0x13 ERROR_NBINIT_MEM_WRITE_STROBE_DELAY_TRAINING Memory write strobe delay training failed EC_XSS Repair Actions/0103

0110

During 2BL memory initialization, if a memory addressing line fails, EC_XSS will be reported. The SMC will retry 4 more times. If on the final attempt, a memory addressing line still fails, the SMC remains in EC_XSS and the 0110 code is displayed on the front panel.

Hex Name Description Type Repair Guide
0x14 ERROR_MEMORY_ADDRESSING Memory address line failed or unresponsive EC_XSS Repair Actions/0110

0111

During 2BL memory initialization, if a memory data line fails, EC_XSS will be reported. The SMC will retry 4 more times. If on the final attempt, a memory data line still fails, the SMC remains in EC_XSS and the 0111 code is displayed on the front panel.

Hex Name Description Type Repair Guide
0x15 ERROR_MEMORY_DATA Memory data line failed or unresponsive EC_XSS Repair Actions/0111

1000

Occurs if kernel communications to the DVD Drive time out. The SMC enters EC_XSS, the E 64 UEM will be displayed, and the 1000 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x40 E 64 ERROR_XSS_CDROM_TIMED_OUT Kernel DVD drive communications timed out EC_XSS Repair Actions/1000

1001

Occurs if the kernel cannot configure the DVD Drive for Direct Memory Access mode. The SMC enters EC_XSS, the E 65 UEM will be displayed, and the 1001 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x41 E 65 ERROR_XSS_CDROM_NOT_DMA_CONFIGURED Kernel could not configure DVD drive for DMA mode EC_XSS Repair Actions/1001

1002

Occurs if the kernel cannot create a device instance for the DVD Drive. The SMC enters EC_XSS, the E 66 UEM will be displayed, and the 1002 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x42 E 66 ERROR_XSS_CDROM_COULD_NOT_CREATE_DEVICE Kernel could not create DVD drive instance EC_XSS Repair Actions/1002

1003

Occurs if kernel communications to the Hard Drive time out. The SMC enters EC_XSS, the E 67 UEM will be displayed, and the 1003 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x43 E 67 ERROR_XSS_HDD_TIMED_OUT Kernel HDD communications timed out EC_XSS Repair Actions/1003

1010

Occurs if the kernel cannot configure the Hard Drive for Direct Memory Access mode. The SMC enters EC_XSS, the E 68 UEM will be displayed, and the 1010 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x44 E 68 ERROR_XSS_HDD_NOT_DMA_CONFIGURED Kernel could not configure HDD for DMA mode EC_XSS Repair Actions/1010

1011

Occurs if the kernel cannot create a device instance for the Hard Drive. The SMC enters EC_XSS, the E 69 UEM will be displayed, and the 1011 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x45 E 69 ERROR_XSS_HDD_COULD_NOT_CREATE_DEVICE Kernel could not create HDD instance EC_XSS Repair Actions/1011

1012

Occurs if a Hard Drive is detected, but the kernel cannot find or access it. The SMC enters EC_XSS, the E 70 UEM will be displayed, and the 1012 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x46 E 70 ERROR_XSS_HDD_NOT_FOUND Kernel couldn't find the HDD EC_XSS Repair Actions/1012

1013

Occurs if XAM cannot find a Dashboard (dash.xex) to load from the Nand. The SMC enters EC_XSS, the E 71 UEM will be displayed, and the 1013 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x47 E 71 ERROR_XSS_XAM_NO_DASH XAM could not find a dash to load EC_XSS Repair Actions/1013

1020

Occurs if the SMC Config on the Nand is missing or corrupt. The SMC enters EC_XSS, the E 72 UEM will be displayed, and the 1020 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x48 E 72 ERROR_SMC_FLASH_CONFIG_CORRUPT SMC configuration area in the nand is corrupt EC_XSS Repair Actions/1020

1021

Occurs if the HSIO training fails due to an unresponsive or malfunctioning eDRAM. The SMC enters EC_XSS, the E 73 UEM will be displayed, and the 1021 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x49 E 73 ERROR_HSIO_TRAINING_FAILED GPU to eDRAM High Speed Link failed EC_XSS Repair Actions/HSIO

1022

Xbox 360 (Original)

Occurs if the HSIO calibration fails due to an unresponsive or malfunctioning eDRAM. The SMC enters EC_XSS, the E 74 UEM will be displayed, and the 1022 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x4A E 74 ERROR_HSIO_CALIBRATION_FAILED GPU to eDRAM High Speed Link failed EC_XSS Repair Actions/HSIO

1023

Occurs if the Southbridge can't communicate with the Ethernet PHY, or the vendor ID of the PHY is incorrect. The SMC enters EC_XSS, the E 75 UEM will be displayed, and the 1023 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x4B E 75 ERROR_UNEXPECTED_ETHERNET_PHY_VENDOR Southbridge could not communicate with Ethernet PHY over MDIO/MDC EC_XSS Repair Actions/1023

1030

Occurs if the Ethernet PHY does not complete the reset sequence properly. The SMC enters EC_XSS, the E 76 UEM will be displayed, and the 1030 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x4C E 76 ERROR_ETHERNET_PHY_RESET_FAIL Ethernet PHY failed to complete reset EC_XSS Repair Actions/1030

1031

Occurs if the Southbridge can't read from or write to the Ethernet PHY. The SMC enters EC_XSS, the E 77 UEM will be displayed, and the 1031 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x4D E 77 ERROR_ETHERNET_PHY_READ_WRITE_FAIL Could not read from or write to Ethernet PHY EC_XSS Repair Actions/1031

1032

Occurs if the GPU design revision is unsupported by the kernel. The SMC enters EC_XSS, the E 78 UEM will be displayed, and the 1032 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x4E E 78 ERROR_UNSUPPORTED_GPU GPU is wrong revision and not supported EC_XSS Repair Actions/1032

1033

Occurs if XAM cannot found on the Nand. The SMC enters EC_XSS, the E 79 UEM will be displayed, and the 1032 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x4F E 79 ERROR_XSS_FLASH_NO_XAM XAM could not be found on the nand EC_XSS Repair Actions/1033

1100

To be determined.

1101

Occurs if XeKeysSecuritySaveSettings fails. The SMC enters EC_XSS, the E 81 UEM will be displayed, and the 1101 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x51 E 81 Unknown XeKeysSecuritySaveSettings failed EC_XSS Repair Actions/1101

1102

Xbox 360 S and Xbox 360 E

Occurs if the HSIO calibration fails due to an unresponsive or malfunctioning eDRAM. The SMC enters EC_XSS, the E 82 UEM will be displayed, and the 1102 code is displayed on the front panel.

Hex UEM Name Description Type Repair Guide
0x52 E 82 ERROR_HSIO_CALIBRATION_FAILED CGPU to eDRAM High Speed Link failed EC_XSS Repair Actions/HSIO