Secondary Error Codes: Difference between revisions

From XenonLibrary
Jump to navigation Jump to search
(Octal450 moved page Error Database to Error Codes)
Tag: New redirect
 
(Removed redirect to Error Codes)
Tag: Removed redirect
Line 1: Line 1:
#REDIRECT [[Error Codes]]
{{See also|Error Codes}}
 
== SMC Errors ==
These errors are generated by the [[SMC|System Management Controller]].
 
=== 0001 ===
{|class="wikitable"
! Hex !! Name !! Description
|-
| 0x01 || ERROR_V_12P0 || ANA_V12P0_PWRGD negated unexpectedly
|}
 
ANA_V12P0_PWRGD is driven high by the [[ANA]] (later [[HANA]]) as long as the V_12P0 rail is within tolerance. If V_12P0 ever drops out of tolerance, the signal is de-asserted, the SMC enters [[#EC_FATAL|EC_FATAL]], and the 0001 error is displayed.

Revision as of 17:28, 5 January 2023

SMC Errors

These errors are generated by the System Management Controller.

0001

Hex Name Description
0x01 ERROR_V_12P0 ANA_V12P0_PWRGD negated unexpectedly

ANA_V12P0_PWRGD is driven high by the ANA (later HANA) as long as the V_12P0 rail is within tolerance. If V_12P0 ever drops out of tolerance, the signal is de-asserted, the SMC enters EC_FATAL, and the 0001 error is displayed.