Repair Actions/0003
Jump to navigation
Jump to search
Note This page is a technician's reference and is not intended to teach diagnosis and repair of electronic circuits. |
Original Xbox 360
- ERROR_V_GPUCORE
VREG_GPU_PWRGD is driven high by the V_GPUCORE controller as long as the rail is within tolerance. If V_GPUCORE ever drops out of tolerance, the signal is de-asserted, causing the SMC to enter EC_FATAL and the 0003 code to be displayed on the front panel.
Short Circuit
- Check if V_GPUCORE is shorted
- If it is, check each phase to localize short
- 2 phases
- Check V_GPUCORE decoupling capacitors near and under GPU
- If all components are fine but the short remains, replace the GPU
VREG Enable and Power Good
- Everything in this section must be checked quickly, as the SMC will shut down power upon entering EC_FATAL
- Check VREG_GPU_EN_N signal components
- If components are fine but the signal is missing, replace Southbridge
- Check VREG_GPU_PWRGD
- If present, replace Southbridge
- If missing, check pullup
VREG Circuit
- Everything in this section must be checked quickly, as the SMC will shut down power upon entering EC_FATAL
- Check if V_GPUCORE voltage is within tolerance
- If it is, replace the PWM driver and recheck PWRGD
- If it isn't, check each VREG phase and PWM driver
- 2 phases