ANA_V12P0_PWRGD is driven high by the [[ANA]] (later [[HANA]]) as long as the [[Power Rails#V_12P0|V_12P0]] rail is within tolerance. If V_12P0 ever drops out of tolerance, the signal is de-asserted, the SMC enters [[#EC_FATAL|EC_FATAL]], and the 0001 error is displayed.
ANA_V12P0_PWRGD is driven high by the [[ANA]] (later [[HANA]]) as long as the [[Power Rails#V_12P0|V_12P0]] rail is within tolerance. If V_12P0 ever drops out of tolerance, the signal is de-asserted, the SMC enters [[Error Codes#EC_FATAL|EC_FATAL]], and the 0001 error is displayed.


{{Debug and Repair}}
{{Debug and Repair}}

Revision as of 16:30, 5 January 2023

SMC Errors

These errors are generated by the System Management Controller.

0001

Hex Name Description
0x01 ERROR_V_12P0 ANA_V12P0_PWRGD negated unexpectedly

ANA_V12P0_PWRGD is driven high by the ANA (later HANA) as long as the V_12P0 rail is within tolerance. If V_12P0 ever drops out of tolerance, the signal is de-asserted, the SMC enters EC_FATAL, and the 0001 error is displayed.