(Created page with "{{See also|Errors|Secondary Error Codes}} {{Note|This page is a technician's reference and is not intended to teach diagnosis and repair of electronic circuits.}} If the Xbox 360 is unresponsive to the power button, the board is died-died. == Standby Power Rails == === V_5P0STBY === * Check if V_5P0STBY is present * If missing, check if V_5P0STBY is shorted ** If it is, check decoupling capacitors and V_5P0DUAL circuit * This rail comes directly from the power sup...") |
No edit summary |
||
Line 18: | Line 18: | ||
* If missing, check if V_3P3STBY is shorted | * If missing, check if V_3P3STBY is shorted | ||
** If it is, check the regulator and decoupling capacitors | ** If it is, check the regulator and decoupling capacitors | ||
* Check circuit components | |||
* Replace the regulator | * Replace the regulator | ||
Line 25: | Line 26: | ||
* If missing, check if V_1P8STBY is shorted | * If missing, check if V_1P8STBY is shorted | ||
** If it is, check the regulator and decoupling capacitors | ** If it is, check the regulator and decoupling capacitors | ||
* Check circuit components | |||
* Replace the regulator | * Replace the regulator | ||
Line 32: | Line 34: | ||
* If missing, check if V_1P2STBY is shorted | * If missing, check if V_1P2STBY is shorted | ||
** If it is, check the regulator and decoupling capacitors | ** If it is, check the regulator and decoupling capacitors | ||
* Check circuit components | |||
* Replace the regulator | * Replace the regulator | ||
Revision as of 15:41, 21 June 2023
Note This page is a technician's reference and is not intended to teach diagnosis and repair of electronic circuits. |
If the Xbox 360 is unresponsive to the power button, the board is died-died.
Standby Power Rails
V_5P0STBY
- Check if V_5P0STBY is present
- If missing, check if V_5P0STBY is shorted
- If it is, check decoupling capacitors and V_5P0DUAL circuit
- This rail comes directly from the power supply
- Check 5V on DC jack
- If missing, check DC jack
V_3P3STBY
- Check if V_3P3STBY is present
- If missing, check if V_3P3STBY is shorted
- If it is, check the regulator and decoupling capacitors
- Check circuit components
- Replace the regulator
V_1P8STBY
- This rail is not present on Corona, Waitsburg, Stingray, and Winchester
- Check if V_1P8STBY is present
- If missing, check if V_1P8STBY is shorted
- If it is, check the regulator and decoupling capacitors
- Check circuit components
- Replace the regulator
V_1P2STBY
- This rail is only present on Corona, Waitsburg, Stingray, and Winchester
- Check if V_1P2STBY is present
- If missing, check if V_1P2STBY is shorted
- If it is, check the regulator and decoupling capacitors
- Check circuit components
- Replace the regulator
V_5P0DUAL
- Only check this rail if all above rails are present
- Check if V_5P0DUAL is present
- If missing, check if V_5P0DUAL is shorted
- If it is, check the regulator and USB ports
- Check if VREG_V5P0_SEL is high
- If it is, check regulator input resistors
- If resistors are fine, replace the regulator
- If low, SMC is not alive, continue below
- If it is, check regulator input resistors