Secondary Error Codes: Difference between revisions

From XenonLibrary
Jump to navigation Jump to search
No edit summary
(Redirected page to Errors#Secondary Error Codes)
Tag: New redirect
 
(53 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{See also|Error Codes}}
#REDIRECT [[Errors#Secondary Error Codes]]
 
== SMC Errors ==
These errors are generated by the [[SMC|System Management Controller]].
 
=== 0001 ===
{|class="wikitable"
! Hex !! Name !! Description
|-
| 0x01 || ERROR_V_12P0 || ANA_V12P0_PWRGD negated unexpectedly
|}
 
ANA_V12P0_PWRGD is driven high by the [[ANA]] (later [[HANA]]) as long as the V_12P0 rail is within tolerance. If V_12P0 ever drops out of tolerance, the signal is de-asserted, the SMC enters [[#EC_FATAL|EC_FATAL]], and the 0001 error is displayed.
 
{{Debug and Repair}}

Latest revision as of 19:53, 5 May 2023