== Clock Generator and Southbridge == | == Clock Generator and Southbridge == | ||
* Replace Clock Generator | * Replace Clock Generator | ||
* If error | * If error not resolved, replace Southbridge | ||
= S and E = | = S and E = |
Latest revision as of 21:04, 6 August 2024
Note This page is a technician's reference. You will need Schematic and/or Boardview files to follow these steps. |
This error has a different meaning on the Original Xbox 360 vs the Xbox 360 S and Xbox 360 E. On the Original Xbox 360, it is only used on [Xenon (Motherboard)|Xenon]] motherboards.
Xenon Original Xbox 360
- ERROR_NO_CLOCKCHIP
The SMC communicates with the Backup Clock Generator via the SMBus. If communication is lost, the SMC enters EC_FATAL and the 0023 code is displayed on the front panel.
Clock Generator Power
- The Clock Generator is powered by V_3P3STBY and V_3P3
- Check that both rails are present at the Clock Generator
SMBus
- Check that SMB_CLK and SMB_DATA are not shorted to ground
- If they are, isolate them at the Clock Generator or ANA
- Replace Clock Generator or ANA as needed
- If still shorted, remove Southbridge and recheck
- If short clears, replace Southbridge
- If they are, isolate them at the Clock Generator or ANA
- Check SMB_CLK and SMB_DATA pullups
Clock Generator and Southbridge
- Replace Clock Generator
- If error not resolved, replace Southbridge
S and E
- ERROR_V_CPUEDRAM
VREG_VEDRAM_PWRGD is driven high by the V_CPUEDRAM controller as long as the rail is within tolerance. If V_CPUEDRAM ever drops out of tolerance, the signal is de-asserted, causing the SMC to enter EC_FATAL and the 0023 code to be displayed on the front panel.
Short Circuit
- Check if V_CPUEDRAM is shorted
- If it is, check circuit components to localize short
- Lift at least 1 pin of the inductor to isolate the rail before checking
Enable and Power Good
- Everything in this section must be checked quickly, as the SMC will shut down power upon entering EC_FATAL
- Check VREG_VEDRAM_EN signal and pulldown
- If pulldown is fine but signal is missing, replace Southbridge
- Check VREG_VEDRAM_PWRGD
- If present, replace Southbridge
- If missing, check pullup
- If pullup is fine, continue below
VREG Circuit
- Everything in this section must be checked quickly, as the SMC will shut down power upon entering EC_FATAL
- Check if V_EDRAM is present
- If it is, replace the PWM driver and recheck PWRGD
- If it isn't, check VREG and PWM driver